Huck C6L Small-Diameter Lockbolt Assemblies are selected when an assembly calls for small-diameter permanent pin-and-collar joints installed from one accessible side. This application guide to the BS 7805 Part 1:1997 type covers concrete end-uses, the specification checklist, correct installation, and where an alternative fastener performs better. Stocked across roughly 4.8 mm to 9.5 mm, they cover general to heavy-duty work.
Typical Applications for Huck C6L Small-Diameter Lockbolt Assembly
The most common settings where these are specified:
- Trailer bodies: small-diameter permanent joints in rails and formed panels.
- Rail interiors: vibration-exposed brackets installed from one accessible side.
- Bus manufacturing: light structural joints formed by swaging a collar onto the pin.
- Sheet-metal production: repeatable pin-and-collar installation without rear-side access.
How to Specify Huck C6L Small-Diameter Lockbolt Assembly for Your Application
- Size: Select on nominal diameter, then on the hole tolerance and fit class — the fit, not the diameter alone, determines whether the part locates or slips. This product spans 4.8 mm–9.5 mm; check the full table below for the exact dimensions of each size.
- Material: Choose the material and finish for the service environment — plated steel for general use, stainless for corrosion resistance.
- Environment: For damp, coastal or chemical exposure prefer A4/316 stainless or a suitable coating; indoors, plated steel or A2 is usually sufficient.
- Standard: This product is supplied to BS 7805 Part 1:1997. Quoting the standard on your order guarantees interchangeable dimensions between suppliers.
Installation & Assembly Practice
- Drill the hole 0.1 mm over the nominal rivet diameter and deburr both sides before setting.
- Grip range must match the total joint thickness — a rivet set outside its grip range clamps poorly and works loose.
Common Selection Mistakes with Huck C6L Small-Diameter Lockbolt Assembly
- Setting a rivet outside its grip range, which leaves the joint loose from day one.
- Using aluminum rivets on steel sheet outdoors — galvanic corrosion eats the rivet.
Where Huck C6L Small-Diameter Lockbolt Assembly Are Not the Right Choice
Not where the joint must later be disassembled, and not for high-tension structural connections.